3.2 Electrical and Mechanical Specifications

Table 错误!文档中没有指定样式的文字。-1 Mechanical and electrical specifications-CDHD2S-1D5/CDHD2S-003
Single phase
AC 120/240V
Rating
Input power circuit: L1,
L2
Continuous current (1 phase Arms)
Control circuit input
power (L1C, L2C)
STO (safety torque
shutdown)
STOFuse(TimeDelay)
Continuous output current [Arms]
Continuous output current (Apeak)
Drive output
Maximum soft-start surge current
Soft start
Circuit power loss
Control circuit loss
—23—
Figure 3-5 CDHD2S-060 (high-voltage) - dimensions (mm)
(120/240 VAC)
Specification
Rated voltage (AC voltage line-
neutral point) ±10%
Line frequency (Hz)
120/240VAC
Line fuse (FWP, or equivalent)
Voltage-endurance (primary to
ground)
120±10 or 240±VAC
STO power supply (DC voltage)
120 or 240 VAC (A)
Peak output current (Arms) 2s
Peak output current (Apeak) 2s
kVA, 120V AC voltage
kVA, 240V AC voltage
PWM frequency (kHz)
(A)
Maximum charging time (ms)
W
W
Medium-voltage
CDHD2S-1D5
120/240
50/60
1Phase
2.5
4
1500VAC (2121VDC)
Single phase
24±10%
1.5
1.5
2.12
4.5
6.3
0.28
0.37
16
7
350
5
Medium-voltage
CDHD2S-003
120/240
50/60
1Phase
5
6
1500VAC (2121VDC)
Single phase
24±10%
1.5
3
4.24
9
12.72
0.44
0.74
16
7
350
5