Replacing the MCU Board
The MCU board (AMETEK Part No. 592130901) is located below the Analog
Interface board. Use Figure 4-11 to locate the MCU board.
To remove the MCU board:
1. Remove the Motor Drive board as described in the section "Removing the
2. Remove the Analog Interface board as described in the previous section.
3. Using a 1/16-inch hex wrench, remove the four (4) standoffs that hold the
To replace the MCU board:
1. Install the new MCU board on the mounting plate using the four (4) stand-
2. Remount the Analog Interface board as described in the previous section.
3. Attach the Motor Driver board as described in the section "Replacing the
Replacing the Fan
The fan (AMETEK Part No. 591090901) is located at the front of the Electronics
Module next to the Stepper Motor. Use Figure 4-11 to locate the fan.
To remove the fan:
1. After locating the fan, use the 1/4-inch nut driver to remove the two (2)
2. Unplug connector P-1 from the Stepper Motor Power Supply board
To replace the fan:
1. Remount the new fan using the nut driver and securing the brackets and
2. Plug connector P-1 back into the Stepper Motor Power Supply board.
4-22 | 5920 UHP Moisture Analyzer
Motor Driver board. "
MCU board in place. Unplug all connectors (Figure 4-14).
offs removed and a 1/16-inch hex wrench.
Motor Driver Board" in this chapter.
nuts in the brackets that hold the fan to the Electronics Module mounting
plate.
cable.
nuts to the Electronics Module mounting plate.