Acquisition Control

Configure image capture settings.
Note: Descriptions of each command can also be found in "AcquisitionControl" (Setting List).
Acquisition Control
Name
AcquisitionLineRate
TriggerMode
TriggerSource
TriggerActivation
ExposureMode
Short
Access
Values
ASCII
1466 ~ 1515152
R/W
LR
Unit: 0.01us
0:Off
R/W
TM
1:On
0: Low
1: High
10-13:
PulseGenerator0-3
14-17: UserOutput0-3
20: Line4 TTL In1
R/W
TI
21: Line5 Opt In1
23: Line7 CC1
24: Line10 TTL In2
26: NAND0 Out
27: NAND1 Out
28: Line13 TTL In3
29: EncoderTrigger
0:Rising Edge
1:Falling Edge
R/W
TA
2: LevelHigh
3: LevelLow
0:Off
R/W
TR
1:Timed
2: TriggerWidth
Default
Value
LR=[Param.]<CR><LF>
LR?<CR><LF>
Use this command to set the line rate of the
1515152
camera by specifying the line period. The unit
value is 1/100 μs.
Example: If you need 68212 Hz = 1466 (14.66
μs line period).
TM=[Param.]<CR><LF>
TM?<CR><LF>
0
Enable/disable the Trigger mode.
TI=[Param.]<CR><LF>
TI?<CR><LF>
20
Select the trigger signal source.
TA=[Param.]<CR><LF>
TA?<CR><LF>
1
Select the polarity of the trigger signal (i.e.,
location of signal at which trigger is applied).
TR=[Param.]<CR><LF>
TR?<CR><LF>
1
Select the exposure mode.