Electronic Shutter - IAI SW-4000T-MCL User Manual

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)

Electronic Shutter

Related Setting Items:
When you use this function, you can set the exposure to a preconfigured accumulation time,
regardless of the line rate.
Variable range: 3 μs to 15.15 ms
l
Variable unit: 0.01 μs (1clk)
l
Supported operation modes: When Trigger Mode ON, Exposure Mode Timed
l
Caution:
In "Trigger Mode Off, Exposure Mode Timed" mode, the line rate configured will be
the maximum value at which the shutter operates. However, in "Trigger Mode ON, Exposure
Mode Timed" mode, the input trigger period will be the maximum value.
Notes:
The exposure offset duration is -0.85 μs.
l
You can also save the setting, and have it applied whenever the power is subsequently
l
turned on, but this requires additional operations.
Switching and settings changing and storage for this function is performed via serial
l
communication.