CounterAndTimerControl

Configure counter settings.
Note: This camera only supports the counter functions.
Related Topic:
Counter and Timer Control Function
CounterAndTimer
Control Item
CounterSelector
CounterEventSource
CounterEventActivation
CounterReset
CounterRefresh
CounterValue
CounterStatus
Setting
Default
Range
Value
0 ~ 3:
0: Counter0
Counter0 ~ 3
-
0: Off
0:Rising
-
Edge
-
-
-
-
-
-
0:
-
CounterIdle
Select the counter.
Assign the Counter Event signal for which you want to read the
count value to a dedicated counter and read the value.
0: Off
1: Line Trigger (Counter0 only)
2: Exposure Start (Counter2 only)
3: Line Start (Counter1 only)
4: Line Transfer End (Counter3 only)
Display the count timing. The setting value is fixed to Rising Edge.
Reset the counter.
Note: Available only when CounterResetSource is set to Software.
Update the counter.
Display the count value.
Display the counter status.
0: CounterIdle
2: CounterActive
4: CounterOverflow - Count value exceeded the maximum value.
- 73 -