Jai Custom Control Shading - IAI SW-4000T-MCL User Manual

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)
Pulse Generator Name
PulseGeneratorClearSyncMode
[PulseGenerator1]
PulseGeneratorClearSyncMode
[PulseGenerator2]
PulseGeneratorClearSyncMode
[PulseGenerator3]

JAI Custom Control Shading

Configure shading correction settings.
Note: Descriptions of each command can also be found in
(Setting List).
Shading Control Name
ShadingCorrectionMode
ShadingMode
PerformShadingCalibration
Short
Access
ASCII
0:Async Mode
R/W
PGSM1
1:Sync Mode
0:Async Mode
R/W
PGSM2
1:Sync Mode
0:Async Mode
R/W
PGSM3
1:Sync Mode
Short
Access
ASCII
0: Flat Shading
R/W
SDCM
1: Color Shading
0: Off
1: User1
R/W
SDM
2: User2
3: User3
W
RS
Values
"JAI Custom Control
Default
Values
Value
0
0
-
-
- 107 -
Short ASCII Command List
Default
Example / Description
Value
PGSM1=[Param.]<CR><LF>
PGSM1?<CR><LF>
0
Selects the sync mode of the
input to clear PulseGenerator1.
PGSM2=[Param.]<CR><LF>
PGSM2?<CR><LF>
0
Selects the sync mode of the
input to clear PulseGenerator2.
PGSM3=[Param.]<CR><LF>
PGSM3?<CR><LF>
0
Selects the sync mode of the
input to clear PulseGenerator3.
Shading"
Example / Description
SDCM=[Param.]<CR><LF>
SDCM?<CR><LF>
Select the shading correction method.
SDM=[Param.]<CR><LF>
SDM?<CR><LF>
Set the area to which to save shading
correction data. When this is set to Off,
PerformShadingCalibration will not be
executed.
RS<CR><LF>
Execute shading correction.
Note: This function cannot be executed
while TestPattern
(Image Format
is being output. A Condition Error is also
displayed when a timeout occurs if the
correction cannot be completed.
Control)

Advertisement

Table of Contents
loading

Table of Contents