① Lens; ② Mounting; ③ Camera Link Cable - IAI SW-4000T-MCL User Manual

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)
① Lens
F-mount or M-52 mount lenses with lens mount protrusions of 13 mm or less can be attached.
Caution:
The maximum performance of the camera may not be realized depending on the
lens.
Notes:
The following formula can be used to estimate the focal length.
Focal length = WD / ( 1 + W/w )
WD: Working distance ( distance between lens and object )
W: Width of object
w: Width of sensor (30.72mm)
② Mounting
When mounting the camera directly to a wall or other device, use screws that match the mounting
holes on the camera (M4: depth 6mm).
Caution:
For heavy lenses, be sure to support the lens itself. Do not use configurations in
which its weight is supported by the camera.
③ Camera Link Cable
Connect the Camera Link cables to the DIGITAL I/O-1 and DIGITAL I/O-2 video output
connectors.
Use Cable Link compatible cables.
l
Refer to the specifications of the cable for details on its bend radius.
l
Caution:
Refer to
the connectors.
Notes on Camera Link Cable Connections
when connecting the cables to