IAI SW-4000T-MCL User Manual page 90

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)
Analog Control
Access
Name
GainInt[DigitalBlue]
R/W
AnalogBaseGain
R/W
[AnalogGreen]
AnalogBaseGain
R/W
[AnalogRed]
AnalogBaseGain
R/W
[AnalogBlue]
BalanceWhiteAuto
R/W
AWBAreaWidth
R/W
AWBAreaOffsetX
R/W
Short
Values
ASCII
IndividualGainMode = Off:
40 ~ 400
GAB
IndividualGainMode = On:
100 ~ 1600
0:0dB
SGG
1:6dB
2:12dB
0:0dB
SGR
1:6dB
2:12dB
0:0dB
SGB
1:6dB
2:12dB
0:Off (Default)
2:Once
4:Exposure Once
AWB
5:Preset 5000K
6:Preset 6500K
7:Preset 7500K
Min / Step: 16(8)*
Max: 4096 (2048)* -
AWBOffsetX
AWBW
Note: *When
BinningHorizontal = 2 ,
the value in parentheses
is applicable.
Min: 0
Max: 4096 (2048)* -
AWBWidth
Step: 16(8)*
AWBO
Note: *When
BinningHorizontal = 2 ,
the value in parentheses
is applicable.
Default
Value
GAB=[Param.]<CR><LF>
GAB?<CR><LF>
100
Set Gain[DigitalBlue]. The setting range varies
depending on the IndividualGainMode setting.
SGG=[Param.]<CR><LF>
SGG?<CR><LF>
0
Set AnalogBaseGain[AnalogGreen].
SGR=[Param.]<CR><LF>
SGR?<CR><LF>
0
Set AnalogBaseGain[AnalogRed].
SGB=[Param.]<CR><LF>
SGB?<CR><LF>
0
Set AnalogBaseGain[AnalogBlue].
AWB=[Param.]<CR><LF>
AWB?<CR><LF>
Set BalanceWhiteAuto. When set to Once, the
automatic adjustment will be performed only
0
once, and then automatically switched to Off.
Note: When set to IndividualGainMode,
only Off can be selected.
AWBW=[Param.]<CR><LF>
AWBW?<CR><LF>
-
Specify the width of the referenced area when
BalanceWhiteAuto is set to Once,
AWBO=[Param.]<CR><LF>
AWBO?<CR><LF>
0
Specify the offset of the referenced area when
BalanceWhiteAuto is set to Once,
- 90 -
Short ASCII Command List
Example / Description

Advertisement

Table of Contents
loading

Table of Contents