To Use The Counter Function - IAI SW-4000T-MCL User Manual

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)

To Use the Counter Function

Configure the settings as follows.
Eight counters are available. Specify a counter (Counter0 to Counter3), and configure the
settings.
Item
Counter 0 ~ 3
CounterEventSource
CounterEventActivation RisingEdge (fixed)
Note: On this camera, the counter event activation is fixed to RisingEdge.
Setting Value
Selectable Range
Counter 0 ~ 3
Counter0: Off, Line Trigger
Counter1: Off, Line Start
Counter2: Off, Exposure Start
Counter3: Off, Line Transfer End
- 57 -
Main Functions
Description
Select the counter.
Select the Counter
Event signal for which to
read the count value.
When set to Off, the
counter operation will
stop (but will not be
reset).
Specify the timing at
which to count.

Advertisement

Table of Contents
loading

Table of Contents