Counter And Timer Control - IAI SW-4000T-MCL User Manual

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)

Counter and Timer Control

Configure counter settings.
Notes:
This camera only supports the counter functions.
l
Descriptions of each command can also be found in "CounterAndTimerControl"
l
(Setting List).
Counter and Timer
Control Name
CounterEventSource
[Counter0]
CounterEventSource
[Counter1]
CounterEventSource
[Counter2]
CounterEventSource
[Counter3]
CounterReset [Counter0]
CounterReset [Counter1]
CounterReset [Counter2]
CounterReset [Counter3]
CounterValue [Counter0]
CounterValue [Counter1]
Short
Access
ASCII
0: Off (Stop the counter)
R/W
CE0
1: Line Trigger (Count the
number of LineTrigger)
0: Off (Stop the counter)
R/W
CE1
1: Line Start (Count the
number of LineStart)
0: Off (Stop the counter)
1: Exposure Start (Count
R/W
CE2
the number of Exposure
Start)
0: Off (Stop the counter)
1: Line Transfer End (Count
R/W
CE3
the number of LineTransfer
End)
W
CR0
-
W
CR1
-
W
CR2
-
W
CR3
-
R
CV0
0 ~ 4294967295
R
CV1
0 ~ 4294967295
Default
Values
Value
0
0
0
0
-
-
-
-
-
-
- 99 -
Short ASCII Command List
Example / Description
CE0=[Param.]<CR><LF>
CE0?<CR><LF>
Select the events that will be the source
to increment the Counter.
CE1=[Param.]<CR><LF>
CE1?<CR><LF>
Select the events that will be the source
to increment the Counter.
CE2=[Param.]<CR><LF>
CE2?<CR><LF>
Select the events that will be the source
to increment the Counter.
CE3=[Param.]<CR><LF>
CE3?<CR><LF>
Select the events that will be the source
to increment the Counter.
CR0<CR><LF>
Reset the Counter0.
CR1<CR><LF>
Reset the Counter1.
CR2<CR><LF>
Reset the Counter2.
CR3<CR><LF>
Reset the Counter3.
CV0?<CR><LF>
Display the Counter0's value.
CV1?<CR><LF>
Display the Counter1's value.

Advertisement

Table of Contents
loading

Table of Contents