Short Ascii Command List; Protocol (Short Ascii Command) - IAI SW-4000T-MCL User Manual

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)
Short ASCII Command List
All configuration of the camera is done via the RS-232C port. The camera can be set up from a
PC running terminal emulator software.
Below is the description of the ASCII based short command protocol.
Communication Setting
Baud Rate: 9600 (Default)
Data Length: 8bit
Start Bit: 1bit
Stop Bit: 1 bit
Parity: None
Xon/Xoff Control: None

Protocol (Short ASCII Command)

Transmit the setting command to camera
NN is any kind of the command.
NN=[Param.]<CR><LF>
Send to camera: GA=0 <CR><LF>
Camera response: COMPLETE<CR><LF>
When camera receives a valid command, camera will return 'COMPLETE'. If camera receives an
invalid command, camera will return following:
Send to camera: GAX=0 <CR><LF>
Camera response: 01 Unknown Command!!<CR><LF>
Send to camera: GA=1000 <CR><LF>
Camera response: 02 Bad Parameters!!<CR><LF>
Transmit the request command to camera
The status of camera's settings can be queried by transmitting NN?<CR><LF>, where NN is any
valid command.
The camera will return the current setting data.
Send to camera: GA? <CR><LF>
Camera response: GA=100<CR><LF>
- 82 -
Short ASCII Command List

Advertisement

Table of Contents
loading

Table of Contents