Configure image capture settings.
Acquisition Control Item Setting Range Default Value
AcquisitionLineRate (Hz)
Related Topic:
Variable Line Rate
TriggerMode
Related Topic:
Trigger Control
TriggerSource
TriggerActivation
ExposureMode
Related Topic:
Exposure Mode
ExposureTimeMode
66 to 67702
66
(steps of 0.1)
0:Off
0:Off
1:On
20: Line4 TTL
-
In1
0:Rising Edge
1:Falling Edge
1:Falling Edge
(falling edge of
3:Level High
input signal)
4:Level Low
0: Off
1: Timed
1: Timed
2: TriggerWidth
0: Common
0: Common
1: Individual
Set the AcquisitionLineRate(Hz).
Select the trigger mode.
Select the trigger signal source.
0: Low
1: High
10-13: PulseGenerator0-3
14-17: UserOutput0-3
20: Line4 TTL In1
21: Line5 Opt In1
23: Line7 CC1
24: Line10 TTL In2
26: NAND0 Out
27: NAND1 Out
28: Line13 TTL In3
29: EncoderTrigger
Select the polarity of the trigger signal (i.e., location of signal at
which trigger is applied).
Select the exposure mode.
Select the Exposure setting method.
Select Common to set a common value for all three sensors.
Select Individual to set the value for each channel.
Note: This item is available only when ExposureMode is set
to Timed.
- 65 -