IAI SW-4000T-MCL User Manual page 76

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)
Pulse Generator Item
PulseGeneratorEndPoint
(ms)
PulseGeneratorPulseWidth
(ms)
PulseGeneratorRepeat
Count
PulseGeneratorClear
Activation
PulseGeneratorClear
Source
Setting Range
Default Value
(1 /
PulseGeneratorClock
(MHz)) to (1048575 /
33.3333
PulseGeneratorClock
(MHz))
-
33.3333
0 ~ 255
0
0: Off
1: Level High
2: Level Low
0: Off
4: Rising Edge
8: Falling Edge
-
0: Low
Set the start point of the Low interval in
milliseconds. When the counter reaches this
value, the output will be 0. The setting range varies
depending on the ClockPreScaler value.
PulseGeneratorEndPoint =
1/PulseGeneratorClock *
PulseGeneratorEndPoint
Display the High interval width of the pulse in
milliseconds. The duration between the Start Point
and End Point is calculated. The setting range
varies depending on the ClockPreScaler value.
PulseGeneratorPulseWidth =
1/PulseGeneratorClock *
(PulseGeneratorEndPoint -
PulseGeneratorStartPoint)
Set the repeat count for the counter. When this is
set to 0, a free counter is enabled with no repeat
limit.
Set the clear signal condition for the count clear
input of the pulse generator.
Select the count clear input signal source.
0: Low
1: High
7: ExposureActive
9: LVAL
10-13: PulseGenerator0-3
14-17: UserOutput0-3
20: Line4: TTL In1
21: Line5: Opt In1
23: Line7 - CC1
24: Line10: TTL In2
26: NAND0 Out
27: NAND1 Out
28: Line13: TTL In3
29: EncoderTriger
30: EncoderDirection
Note: (※)Disabled if the PulseGenerator is selected
in PUlseGeneratorSelector.
- 76 -
Setting List
Description

Advertisement