IAI SW-4000T-MCL User Manual page 103

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)
Pulse Generator Name
PulseGeneratorStartPoint
[PulseGenerator1]
PulseGeneratorStartPoint
[PulseGenerator2]
PulseGeneratorStartPoint
[PulseGenerator3]
PulseGeneratorEndPoint
[PulseGenerator0]
PulseGeneratorEndPoint
[PulseGenerator1]
PulseGeneratorEndPoint
[PulseGenerator2]
Short
Access
ASCII
R/W
PGST1 0 ~ 1048575
R/W
PGST2 0 ~ 1048575
R/W
PGST3 0 ~ 1048575
R/W
PGEN0 0 ~ 1048575
R/W
PGEN1 0 ~ 1048575
R/W
PGEN2 0 ~ 1048575
- 103 -
Default
Values
Value
0
0
0
0
0
0
Short ASCII Command List
Example / Description
PGST1=[Param.]<CR><LF>
PGST1?<CR><LF>
Set the start point of the High
interval as a clock count for
PulseGenerator1. When the
counter reaches this value, the
output will be 1.
PGST2=[Param.]<CR><LF>
PGST2?<CR><LF>
Set the start point of the High
interval as a clock count for
PulseGenerator2. When the
counter reaches this value, the
output will be 1.
PGST3=[Param.]<CR><LF>
PGST3?<CR><LF>
Set the start point of the High
interval as a clock count for
PulseGenerator3. When the
counter reaches this value, the
output will be 1.
PGEN0=[Param.]<CR><LF>
PGEN0?<CR><LF>
Set the start point of the Low
interval as a clock count for
PulseGenerator0. When the
counter reaches this value, the
output will be 0.
PGEN1=[Param.]<CR><LF>
PGEN1?<CR><LF>
Set the start point of the Low
interval as a clock count for
PulseGenerator1. When the
counter reaches this value, the
output will be 0.
PGEN2=[Param.]<CR><LF>
PGEN2?<CR><LF>
Set the start point of the Low
interval as a clock count for
PulseGenerator2. When the
counter reaches this value, the
output will be 0.