Image Format Control

Configure image format settings.
Note: Descriptions of each command can also be found in "ImageFormatControl" (Setting
List).
Image Format
Access
Control Name
Width
R/W
OffsetX
R/W
BinningHorizontal
R/W
BinningVertical
R/W
PixelFormat
R/W
TestPattern
R/W
SensorType
R/W
Short
Values
ASCII
Min / Step: 16
(8)*
WTC
Max: 4096
(2048)* - OffsetX
Min: 0
Max: 4096
OFC
(2048)* - Width
Step: 16 (8)*
1: Off
HB
2: On
1: Off
VB
2: On
0: RGB8
BA
1: RGB10
0:Off
1:White
2:GreyPattern1
TPN
(Ramp)
3:GreyPattern2
(Stripe)
4:ColorBar
0:TypeA (7.5um
x 7.5 um)
STP
1:TypeB (7.5um
x 10.5um)
Default
Example / Description
Value
WTC=[Param.]<CR><LF>
WTC?<CR><LF>
Set the image width.
4096
Note: *When BinningHorizontal = 2 or ImageScalingMode
= On, the value in parentheses is applicable.
OFC=[Param.]<CR><LF>
OFC?<CR><LF>
Set the horizontal offset.
0
Note: *When BinningHorizontal = 2 or ImageScalingMode
= On, the value in parentheses is applicable.
HB=[Param.]<CR><LF>
HB?<CR><LF>
1
Set the number of pixels in the horizontal direction for
which to perform binning.
VB=[Param.]<CR><LF>
VB?<CR><LF>
1
Set the number of pixels in the vertical direction for which
to perform binning.
BA=[Param.]<CR><LF>
BA?<CR><LF>
0
Set the pixel format.
TPN=[Param.]<CR><LF>
TPN?<CR><LF>
0
Select the test image.
STP=[Param.]<CR><LF>
STP?<CR><LF>
0
Set the sensor type.
- 86 -