Lutcontrol - IAI SW-4000T-MCL User Manual

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)
Analog Control Item
AGCOnceStatus
Gamma
Related Topic:
Gamma Function
LUTMode

LUTControl

Configure LUT settings.
Related Topic:
LUT (Lookup Table)
LUT Control Item
LUTSelector
LUTIndex
LUTValue
Default
Setting Range
Value
-
-
0.45 ~ 1
0.45
0: Off
1: Gamma
0:Off
2: LUT
Setting Range
0: Red
1: Green
0: Red
2: Blue
0 ~ 256
0
0 ~ 4095
Gamma≒ 1.0
Display the status when GainAuto is set to Once.
1: Succeeded.
2: Error1- Timeout-error occurred.
3: Abort1-Control Limit
4: IDLE (Default)
Set the Gamma value.
Setting Range: 0.45, 0.50, 0.55, 0.60, 0.65, 0.75, 0.80, 0.90, 1.00
Set the LUT mode.
Default Value
Select the LUT channel to control.
Note: Color models only.
Set the LUT index table number.
Set the LUT value.
- 69 -
Description
Description
Setting List