Package Contents - IAI SW-4000T-MCL User Manual

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)
Item
Connectors / LEDs
Notes:
Design and specifications are subject to change without notice.
l
Approximately 30 minutes of warm-up are required to achieve these specifications.
l
Caution: About the verified performance temperature
Make sure the following temperature conditions are met when operating the unit.
1) The camera's internal temperature sensor detects temperatures of 67 °C or less during
operation.
2) The top surface of the camera's casing is 57 °C or less.
If the above temperature conditions are exceeded, take measures to dissipate heat according
to your installation environment and conditions.

Package Contents

Camera body (1)
l
Sensor protection cap (1)
l
Dear Customer (sheet) (1)
l
Model: HDR-EC26FYTG2-SLt × 2
Mini Camera Link
Function: video output / communication / external trigger / ExposureActive
*Positive polarity for ExposureActive (polarity switching not possible)
Model: HR10A-10R-12PB(71) (or equivalent)
12-pin
Function: power supply input / communication / external trigger / ExposureActive
*Negative polarity for ExposureActive (polarity switching not possible)
Model: Camera side: 3260-10S3 (55) (Equivalent to Hirose Electronic), Cable
side:3240-10P-C(50) (Equivalent to Hirose Electronic)
10-pin
Function: communication
LED
Function: Power on, trigger input indicator
RGB
- 118 -
Miscellaneous

Advertisement

Table of Contents
loading