Digital IO Control Item
LineSource
LineStatusAll
OptInFilterSelector
UserOutputSelector
UserOutputValue
Default
Setting Range
Value
0: Low
1: High
7: ExposureActive
9: LVAL
10: PulseGenerator0
11: PulseGenerator1
12: PulseGenerator2
13: PulseGenerator3
14: UserOutput0
15: UserOutput1
16: UserOutput2
0: Low
17: UserOutput3
20: Line4: TTL In1
21: Line5: Opt In1
23: Line7 - CC1
24: Line10: TTL In2
26: NAND0 Out
27: NAND1 Out
28: Line13: TTL In3
29: EncoderTriger
30: EncoderDirection
bit0:Line1
-
(TTL
Out1)
0: Off
1: 0.1 us
2: 1 us
3: 5 us
0: Off
4: 10 us
5: 50 us
6: 100 us
0: User Output 0
1: User Output 1
0
2: User Output 2
3: User Output 3
0: False
0: False
1: True
Select the line source signal for the item selected in LineSelector.
Display the input/output signal status.
Remove noise from the OptIn input signal of Digital I/O.
Set the UserOutput signal.
Set the value for the UserOutput selected in UserOutputSelector.