IAI SW-4000T-MCL User Manual page 98

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)
Digital IO Control
Name
LineSource
[NANDGate0In1]
LineSource
[NANDGate0In2]
LineSource
[NANDGate1In1]
LineSource
[NANDGate1In2]
OptInFilterSelector
UserOutputValue
[UserOutput0]
UserOutputValue
[UserOutput1]
UserOutputValue
[UserOutput2]
UserOutputValue
[UserOutput3]
Short
Access
ASCII
R/W
ND0IN1
Same as LS0
R/W
ND0IN2
Same as LS0
R/W
ND1IN1
Same as LS0
R/W
ND1IN2
Same as LS0
0: Off
1: 0.1 us
2: 1 us
R/W
OPTFL
3: 5 us
4: 10 us
5: 50 us
6: 100 us
0: False
R/W
USC0
1: True
0: False
R/W
USC1
1: True
0: False
R/W
USC2
1: True
0: False
R/W
USC3
1: True
Default
Values
Value
0
0
0
0
0
0
0
0
0
- 98 -
Short ASCII Command List
Example / Description
ND0IN1=[Param.]<CR><LF>
ND0IN1?<CR><LF>
Select signal to be passed to the Line
NANDGate0In1.
ND0IN2 =[Param.]<CR><LF>
ND0IN2?<CR><LF>
Select signal to be passed to the Line
NANDGate0In2.
ND1IN1 =[Param.]<CR><LF>
ND1IN1 ?<CR><LF>
Select signal to be passed to the Line
NANDGate1In1.
ND1IN2 =[Param.]<CR><LF>
ND1IN2 ?<CR><LF>
Select signal to be passed to the Line
NANDGate1In2.
OPTFL=[Param.]<CR><LF>
OPTFL?<CR><LF>
Set the noise elimination level of OptIO
input signal of DigitalIO.
USC0 =[Param.]<CR><LF>
USC0 ?<CR><LF>
Set the value (False or True) for the
UserOutput0.
USC1 =[Param.]<CR><LF>
USC1 ?<CR><LF>
Set the value (False or True) for the
UserOutput1.
USC2 =[Param.]<CR><LF>
USC2 ?<CR><LF>
Set the value (False or True) for the
UserOutput2.
USC3 =[Param.]<CR><LF>
USC3 ?<CR><LF>
Set the value (False or True) for the
UserOutput3.