Digitaliocontrol - IAI SW-4000T-MCL User Manual

3 cmos prism line scan camera with mini camera link interface
Table of Contents

Advertisement

SW-4000T-MCL User Manual (2.0)

DigitalIOControl

Configure settings for digital input/output.
Related Topic:
GPIO (Digital Input/Output Settings)
Digital IO Control Item
LineSelector
LineMode
LineFormat
LineInverter
LineStatus
Default
Setting Range
Value
(IO Connecter)
Line5: Opt In1
Line4: TTL In1
Line1: TTL Out1
Line12: TTL Out4
(AUX)
Line10: TTL In2
Line1:
Line13: TTL In3
TTL Out1
Line8: TTL Out2
Line9: TTL Out3
(NAND)
NAND Gate 0 In 1
NAND Gate 1 In 1
NAND Gate 0 In 2
NAND Gate 1 In 2
Input
Output
-
0: False
0: False
1: True
0: False (Low)
0: False
1: True (High)
Select the input/output to configure.
-
Display the input/output status (whether it is input or output).
Display the signal format.
0: NoConnect
-
2: TTL
5: Opto Coupled
7: Internal Signal
Enable/disable polarity inversion for the selected input signal or
output signal.
Display the status of the input signal or output signal (True: High,
False: Low).