Acquisition Control Item Setting Range Default Value
ExposureTimeSelector
ExposureTime (us)
Related Topic:
Electronic Shutter
RBExposureInterlocked
AutoReset
RBExposureInterlocked
AcquisitionLineRateMin
ExposureTimeMin
ExposureTimeMax
0: Common
1:Red
0: Common
2:Green
3:Blue
300 ~1514908
-
0: Off
0: Off
1:On
0: Off
0: Off
1: On
0: Off
0: Off
1:On
-
-
-
-
-
-
Specify the sensor for which to set the ExposureTime. Select
Common if ExposureTimeMode is set to Common. Select
Red/Green/Blue if ExposureTimeMode is set to Individual.
Note: This item is available only when ExposureMode is set
to Timed.
Set the exposure time (0.01 μs) for the channel selected in
ExposureTimeSelector.
Note: The actual exposure time will consist of the image sensor's
offset duration (0.85us) deducted from the ExposureTime setting.
If set to On, you can change Green while maintaining white
balance.
After trigger input is interrupted for a prolonged period (52 msec or
more TBD) when ExposureMode is set to Off and TriggerMode is
set to On, the over-exposed image exposed during the interruption
is output after the first trigger input after resumption. When
AutoReset mode is enabled, LVAL and DVAL images are not
output during interruption, and LVAL and DVAL image output is
resumed after the second trigger input.
If set to On, you can change Green while maintaining white balance
Check the minimum value of AcquisitionLineRate.
Check the minimum value of ExposureTime.
Check the maximum value of ExposureTime.