Step 3: Verifying the Camera Connection Status

When the necessary devices are connected and power is supplied to the camera, the POWER/TRIG
LED at the rear of the camera lights amber, and initialization of the camera starts.
When initialization is complete, the POWER/TRIG LED lights green.
Verify whether power is being supplied to the camera and whether the camera is operational by
checking the rear LED.
Lit green
Press to adjust the One
Push channel balance.
™ For details on how to read the LED, see "LED status and camera status" (page 10) in the "Parts Identification"
section.
Note
If the POWER/TRIG LED does not switch to green within minutes of supplying power, check the Camera Link cable
and other connections.

Step 4: Configuring Basic Settings for the Camera

Start Control Tool, connect the camera to the frame grabber board, and configure initial settings for the
output format.

Connecting to the Camera to Control Tool

1
Start JAI Control Tool.
Cameras connected to the frame grabber board are detected, and a window appears. If they do
not appear, right-click inside the window and select [Search for Cameras].
2
Select the camera you want to configure.
3
Check that the settings of the selected camera are displayed.

Configuring the Output Format

The camera is equipped with two sensors. You can specify whether to output the images of the two
sensors as a single screen or separately via two ports. You can also specify whether the two sensors
operate identically or independently according to individual settings.
Item
JAI Custom
Device TG Mode
Control
CL Type
During normal status
Sync (sensors synced), Async (sensors not synced)
™ [Async] is selectable when [CL Type] is set to [Dual Base].
2 Channel (output as one screen), Dual Base (output separately via two
ports)