Control Without External Triggers; Step 5:Adjusting The Image Quality - IAI SW-4000M-PMCL User Manual

Monochrome line scan camera
Table of Contents

Advertisement

2
Set [Exposure Mode] to [Trigger Width] .
3
If necessary, change the [Trigger Source] and [Trigger Activation] settings.

Control Without External Triggers

When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
Trigger Selector (trigger operation)
Trigger Mode
Exposure Mode
Exposure Time
1
Set [Exposure Mode] to [Timed].
([Timed] is the default setting.)
2
Set [Trigger Mode] to [On].
3
Specify a line period slower than the exposure time in [Acquisition Line rate].
4
Specify the exposure time in [Exposure Time].
When Not Controlling the Exposure Time
Configure the settings as follows.
Item
Exposure Mode
The exposure will be performed with an exposure time equal to Line Period minus 3.6 µs.
Step 5: Adjusting the Image Quality
To maximize the performance of the camera, configure its basic function in the following order.
* For details on this setting, "Variable Line Rate" and "Electronic Shutter". The exposure times and line rates that
can be set will vary depending on the CL clock and Tap Geometry settings for Camera Link.
1
Configure the gain.
For details on this setting, see "Gain Control".
Configure the exposure time.
2
Item
Off
— 16 —
Setting value / selectable range
Line Start
Off
Timed (control via exposure time)
Varies depending on the Tap Geometry and CL Pixel Clock
settings.
Setting value / selectable range
SW-4000M-PMCL

Advertisement

Table of Contents
loading

Table of Contents