Control Without External Triggers

When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
Trigger Selector (trigger operation)
Trigger Mode
Exposure Mode
Exposure Time
Set [Exposure Mode] to [Timed].
1
([Timed] is the default setting.)
Set [Trigger Mode] to [On].
2
Specify a line period slower than the exposure time in [Acquisition Line rate].
3
Specify the exposure time in [Exposure Time].
4
When Not Controlling the Exposure Time
Configure the settings as follows.
Item
Exposure Mode
The exposure will be performed with an exposure time equal to Line Period minus 3.8 µs.
Step 5: Adjusting the Image Quality
To maximize the performance of the camera, configure its basic function in the following order.
* For details on this setting, "Variable Line Rate" (page 33) and "Electronic Shutter" (page 34). The exposure
times and line rates that can be set will vary depending on the CL clock and Tap Geometry settings for Camera
Link.
Configure the gain.
1
For details on this setting, see "Gain Control" (page 31).
Configure the exposure time.
2
Perform DSNU calibration.
3
The camera is equipped with a DSNU correction function. The function allows you to reduce DSNU
generated by the sensor. To use the function, calibration must be performed within the camera and correction
data must be created beforehand.
Item
Off
— 16 —
Setting value / selectable range
Line Start
Off
Timed (control via exposure time)
Varies depending on the Tap Geometry and CL Pixel Clock
settings.
Setting value / selectable range