Setting The Sewing Speed Parameters - Dürkopp Adler D869 e-con Service Instructions Manual

Hide thumbs Also See for D869 e-con:
Table of Contents

Advertisement

Programming

17.4.3 Setting the Sewing speed parameters

Various settings can be made for the sewing speed. The possibilities are
explained in more detail in the table.
Icon
Service Instructions D869 e-con - 00.0 - 09/2023
Menu item
Max. Speed
Maximum permissible speed; it can no
longer be exceeded on the operator level.
Min. Speed
Minimum speed at which an individual
stitch is made; a lower speed is no longer
possible at operator level.
Position speed
The last stitch is executed more slowly
during stopping of the sewing procedure.
Soft start speed
Reduced sewing speed for the first
stitches when sewing begins to sew on the
material securely
Number of soft start stitches
Acceleration
Slope of the acceleration ramp
Deceleration
Slope of the deceleration ramp
Speed limitation DB3000
Reduction of the speed to 3000 (rpm) in
combination with an activated input signal
Speed limitation DB2000
Reduction of the speed to 2000 (rpm) in
combination with an activated input signal
Value range
• Value range
0500 - 2800 [rpm],
depending on subclass
• Value range
050 - 400 [rpm]
• Value range
010 - 700 [rpm]
• Value range
0010 - 1000 [rpm]
• Value range
00 - 10 [stitches]
• Value range
01 - 40 [(rpm)/ms]
• Value range
01 - 40 [(rpm)/ms]
• Value range
150-9999 [rpm]
• Value range
150-9999 [rpm]
121

Advertisement

Table of Contents
loading