Dürkopp Adler D869 e-con Service Instructions Manual page 218

Hide thumbs Also See for D869 e-con:
Table of Contents

Advertisement

4460
4905
4906
4907
4908
4911
4918
4919
4920
4921
4922
4923
4924
4925
4926
4930
4931
6070
6353
6360
6361
6362
6363
6364
216
Code
Type
Meaning
Warning
OP7000 connection lost
Information
New machine is connected
Information
Information
Information
Information
Warning
Invalid update file
Warning
Reset failed
Warning
Update protocol failure
Warning
Update was interrupted
Error
No User Database found
Error
Sync failed
Warning
Control not responding
Warning
Sync failed
Warning
Sync failed
Information
Control replaced
Information
Checksum failure of control
Error
Internal CAN
Error
EEprom Timeout
Information
No valid data on external EEprom
(internal data structures are not
compatible with the external data
storage device)
Information
No external EEprom connected
Information
No valid data on internal EEprom
(internal data structures are not
compatible with the external data
storage device)
Information
No valid data on internal and external
EEprom (software version is not
compatible with the internal data
storage device, emergency operating
features only)
Information
No valid data on internal EEprom and
no external EEprom connected
(the internal data structures are not
compatible with the external data
storage device)
Troubleshooting
Corrective
• Check connection to OP7000
• Replace OP7000
• Replace the control
• New machine is connected
• Set the class in the Service menu
• Check machine ID port
• Reset or machine class change
necessary
• Reset or machine class change
necessary
• Reset necessary
• Reset necessary
• Contact DA Service
• Contact DA Service
• Contact DA Service
• Contact DA Service
• Contact DA Service
• Contact DA Service
• Perform software update
• Contact DA Service
• Contact DA Service
• Data from operation panel will be
stored to control
• Data from operation panel will be
stored to control
• Perform software update
• Replace the control
• Switch off the control, wait until the
LEDs are off, check connection for
machine ID, and switch on control
again
• Software update
• Connect machine ID
• Check machine ID connection
• Switch off the control, wait until
the LEDs have gone out, and then
switch on the control again
• Software update
• Check machine ID connection
• Switch off the control, wait until
the LEDs have gone out, and then
switch on the control again
• Software update
• Check machine ID connection
• Switch off the control, wait until
the LEDs have gone out, and then
switch on the control again
• Software update
Service Instructions D869 e-con - 00.0 - 09/2023