Moving the feed dog
Fig. 35: Moving the feed dog
(1) - Screw
(2) - Lever
(3) - Feed dog carrier
To move the feed dog:
1. Execute the service routine Feed dog > Position to needle
2. Press Next.
 The software is used to define the necessary presettings on
3. Press the Service Stop button.
4. Disassemble the throat plate ( p. 27).
5. Loosen screws (1) and (5).
6. Loosen the threaded pins on the stroke eccentric (4).
7. Move the feed dog carrier (3).
8. Tighten screws (1) and (5).
9. Finish the service routine.
48
( p. 14).
the machine.
Place the removed throat plate next to it as an aid for orientation so
that the feed dog can be screwed on straight.
Adjusting feed dog and needle bar linkage
(4) - Threaded pin on the stroke eccentric
(5) - Screw
Service Instructions D869 e-con - 00.0 - 09/2023