Parameter
Parameter Seam Begin
Needle thread clamp
The needle thread clamp is closed at
st
the 1
the needle thread lies on the underside
of the sewing material
Seam begin bartack settings
Bartack at seam begin
Number of stitches backwards
Number of stitches forward
Number of bartack sections
A bartack consists of several sections.
If the sewing direction is changed, a
new section is started. The number of
sections in a bartack can be set here.
Stop-Time for direction change
The waiting time at the turning points
(e.g. for a change of sewing direction) is
set at this point. A short waiting time in
milliseconds should ensure consistent
seam quality (ornamental-stitch bartack)
88
5.6.4

Setting the Segment Begin parameters

There are various options for setting the Segment Begin param-
eters. The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
stitch of the seam to ensure that
Operating Instructions D669 M-TYPE DELTA - 00.0 - 10/2020
Setting
Value range
On/Off
Value range
On/Off
Value range
01 - 50
Value range
01 - 50
Value range
01 - 99
Value range
0000 – 1000 [ms]