Height Calibration of Edge Guide (only for 2-axis edge guide)
To calibrate the height of the edge guide:
1. Call up the Service > Calibration > Edge Guide Height
The control panel displays the value 5 mm.
2. Place the locking peg included in the accessories under the edge guide.
3. Use the -/+ buttons to move the edge guide until the edge guide slightly
4. Confirm the entry with Next.
The calibration is complete.
Calibration of the Pedal
To calibrate the position of the pedal:
1. Follow the instructions on the control panel and press the pedal fully
2. Press Next.
3. Press the pedal halfway back to the -1 position.
4. Press Next.
5. Release the pedal (position 0).
6. Press Next.
7. Press the pedal forward to the +1 position.
8. Press Next.
Calibration complete.
9. Press Close.
172
menu item.
clamps the locking peg.
The value on the display will NOT change.
back to the specified -2 position.
Service Instructions D869 e-con - 00.0 - 09/2023
Programming