Height Calibration of Edge Guide (only for 2-axis edge guide)
To calibrate the height of the edge guide:
1. Call up the Service > Calibration > Edge Guide Height
 The control panel displays the value 5 mm.
2. Place the locking peg included in the accessories under the edge guide.
3. Use the -/+ buttons to move the edge guide until the edge guide slightly
4. Confirm the entry with Next.
 The calibration is complete.
Calibration of the Pedal
To calibrate the position of the pedal:
1. Follow the instructions on the control panel and press the pedal fully
2. Press Next.
3. Press the pedal halfway back to the -1 position.
4. Press Next.
5. Release the pedal (position 0).
6. Press Next.
7. Press the pedal forward to the +1 position.
8. Press Next.
 Calibration complete.
9. Press Close.
172
menu item.
clamps the locking peg.
The value on the display will NOT change.
back to the specified -2 position.