17.4.17 Setting the Edge Guide parameters

Various settings can be made for the edge guide (motor driven).
The possibilities are explained in more detail in the table
Icon
138
NOTICE
Property damage may occur!
Sewing feet, needle, edge guide and sewing equipment can be
damaged.
ALWAYS check the distance to the edge guide and input the correct
value after changing the sewing equipment.
Menu items
Edge guide
Edge Guide Mode
Motor driven
Speed
Travel speed of the edge guide
Min. gap
Smallest possible gap between the sewing
foot and the edge guide.
The smallest possible distance depends
on the sewing equipment and MUST be
adapted after a change of the sewing
equipment.
.
Value range
• Value range
On/Off
• Value range
1-axis (X) external
module/
2-axes (X+Z) external
module/
2-axes (X+Z) external
module, X axis
direction inverted/
2-axes (X+Z) external
module; center guide
function
• Value range
On/Off
• Value range
05000 - 60000 [Hz]
• Value range
00.1 – 36.0 [mm]