Download Print this page

Tiller Handle Model - TOHATSU MFS 8B Service Manual

4 stroke
Hide thumbs Also See for MFS 8B:

Advertisement

1.
Remove cable terminal holder cover.
2.
Disconnect cable coupler from exciter coil, and measure
resistance.
This test can be made without removing parts.
Exciter Coil Resistance (Reference value) :
 Between Black/Red (B/R) - Blue (L) : 236 - 354 kΩ
Check the connection by referring to coupler
connection chart
terminal holder cover.
Remote control model
Remove the part and test it as a separate unit.
1.
Check electrical conductivity of oil pressure switch. Replace
if no conductivity.
2.
Connect vacuum/pressure gauge to oil pressure switch.
Vacuum/Pressure Gauge :
 P/N. 3AC-99020-0
8-14
located on the back of cable

Tiller handle model

4st 8/9.8 2016

Advertisement

loading

This manual is also suitable for:

Mfs 9.8b