1.
Turn manual valve
2.
Put PT unit
on the work bench vertically, remove cap
and check level of fluid in the reservoir.
3.
Add recommended PT fluid to specified level if it is lacking.
Recommended PT Fluid :
ATF DEXRON II
4.
Put cap
and tighten to specified torque.
Reserve Tank Cap :
1.5N ・ m (1.1lb ・ ft) [1.5kgf ・ m]
5.
Reconnect PT motor lead wires to battery terminals to fully
retract tilt rod.
Tilt Rod
DOWN
6.
Reconnect PT motor lead wires to battery terminals to fully
extend tilt rod.
Tilt Rod
UP
Repeat above steps several times to move up
and down tilt rod (When reversing motor lead
wire connection, keep the connection open for
two or three seconds.).
7.
Check fluid level with tilt rod fully stretched.
Add recommended PT fluid to specified level if it is lacking.
Recommended PT Fluid :
ATF DEXRON II
8.
Repeat steps 2. to 7. until fluid reaches specified level.
9.
Reattach cap.
7-46
clockwise fully.
PT motor lead wires
Battery Terminals
Green (G)
+ : Positive Terminal
Blue (L)
− : Negative Terminal
Battery Terminals
PT motor lead wires
Blue (L)
+ : Positive Terminal
Green (G)
− : Negative Terminal