1.
Check water strainer
2.
Set outboard motor in the water and start engine.
3.
Check that cooling water is discharged from cooling water
check port
. If not, check water pump and cooling water
passage in the engine.
Flushing with water using flusher
1.
Remove propeller and thrust holder.
2.
Attach flushing kit or flusher
connect water hose to the attachment, and run water.
3.
Set gear shift to neutral (N) and start engine.
4.
Check that cooling water check port discharges water, and
run engine for 3 to 5 minutes at low speed.
5.
Stop engine and stop water supply, remove flusher
remove tape, and then, install propeller.
3-30
for clogging. Clean if necessary.
to water strainer
,
, and
4st 8/9.8 2016