Get/Put Drives Dialog

Path: Main Menu Service Menu Diags
Submenu Gripper Submenu Get/Put Drives
Dialog
Use the Get/Put Drives dialog to start an existing GET
and PUT of all cartridges in a specified range to a specific
drive. See Figure 5-172.
The menu selection supports all tape drive models except
TD-3610, 3590-B1A, and 3590-E1A.
The gripper test will
get/put media
Cycles to run:
Figure 5-172

Get/Put Drives Dialog

Parameter
Cycles to run
[more]
When [more] is selected, the Continuation Dialog
appears. See Figure 5-173 on page 5-125.
Enter SOURCE
Coordinate : D 01 1< A 01
OR Element : 01200
Accept : N
Figure 5-173
Continuation Dialog
Parameter
Coord
009<
[more]
Value
Indicates the number of cycles
to run (1–999).
More selections on the
Continuation Menu.
Value
The first field indicates the
type of cell (I for I/E Station, D
for Drive, S for Storage cell).
The second field displays
module numbers that can be
modified if EMs are present (1–
4).
The third field indicates the
Service Menu 5-125