Table 7-1
Reported
SAC
75
A failure is detected in the Gripper Assembly.
Action 1
Perform a Teach Current operation (Main Menu
Current).
Action 2
If the problem is not corrected or persists, contact ATAC. For contact
information, refer to ADIC Technical Assistance Center on page 1-5.
76
A Teach failure is caused by the Accessor out of alignment condition.
Action 1
Perform a Teach Current operation (Main Menu
Current).
Action 2
If the problem is not corrected or persists, contact ATAC. For contact
information, refer to ADIC Technical Assistance Center on page 1-5.
77
Failures detected in the Gripper Assembly during a Retract operation.
Action 1
Perform a Teach Current operation (Main Menu
Current).
Action 2
If the problem is not corrected or persists, contact ATAC. For contact
information, refer to ADIC Technical Assistance Center on page 1-5.
7-14
Error Messages
SAC Reporting (Continued)
Perform these actions
Service
Teach
Teach
Service
Teach
Teach
Service
Teach
Teach
6-00054-02 Rev A