Table 7-1
Reported
SAC
43
An unknown library configuration id detected, the barcode scanner is unable
to read the fiducial label located in the 4x12 (4x18 AIT) or the 5x12 (5x18 AIT)
Storage Assembly during a Teach operation. See Figure 2-2 on page 2-9 for
more information on Storage Assembly locations.
Action 1
Contact ATAC. For contact information, refer to ADIC Technical Assistance
Center on page 1-5.
44
An unknown fiducial label is detected during a Teach operation.
Action 1
Contact ATAC. For contact information, refer to ADIC Technical Assistance
Center on page 1-5.
45
During a Get or Put operation, the calculated X position exceeded the
allowable limits.
Action 1
Contact ATAC. For contact information, refer to ADIC Technical Assistance
Center on page 1-5.
46
During a Get or Put operation, the calculated Y position exceeded the
allowable limits.
Action 1
Contact ATAC. For contact information, refer to ADIC Technical Assistance
Center on page 1-5.
50
A tape cartridge is not properly seated in the storage cell.
Action 1
Make sure the tape cartridge in question is properly installed in its storage cell.
Action 2
Reteach the library using the Operator Panel.
(Main Menu Service Teach Teach New)
Action 3
If the problem is not corrected or persists, contact ATAC. For contact
information, refer to ADIC Technical Assistance Center on page 1-5.
22 June 2004
SAC Reporting (Continued)
Perform these actions
Service Action Codes
7-11