Quantum Scalar 1000 Release Note

Quantum scalar 1000: release note
Hide thumbs Also See for Scalar 1000:

Advertisement

Release Notes

®
Product: Scalar
1000 641A.00003
Date: December 2006
Contents
Page
1

Purpose of this Release

1

New Enhancement

2
Compatibility Matrix
3
Resolved Issues
4
Known Issues
4
Documentation
Purpose of this Release
This Scalar 1000 641 firmware release adds one new enhancement that extend the capabilities of the
Scalar 1000 Library. This document describes the new enhancement, as well as corrections made to issues
encountered in previous releases of the library. Visit
Scalar 1000 641 Firmware and previous releases.
New Enhancement
The following enhancement is in this release of the Scalar 1000:
Improved label scanning during teaching
Previously, teach values could vary as much as 2mm between teaches, which could generate SAC
7C errors.
To improve scanning accuracy and reduce variance errors, labels are now scanned at least twice.
If the X or Y value exceeds 0.5mm, either X, Y, or both are scanned again. After scanning, the
largest X value and smallest Y value are passed to the teach function to calculate cell positions.
Also, to help eliminate SAC 7B errors that occurred during teach mastering, the reach motor
extends 1mm farther while extending to the teach master bracket.
Finally, to alert users when a scanner might need replacing, during the teach a warning message
appears on the operator panel when the scan beam is not level or is jittery.
© December 2006, ADIC®
ADIC and Scalar are registered trademarks of Advanced Digital Information Corporation. All
other product, company, or service names mentioned herein are the property of their respec-
tive owners.
Topic
www.adic.com
for additional information about
6-00017-26 Rev A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Scalar 1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Quantum Scalar 1000

  • Page 1: Release Notes

    Documentation Purpose of this Release This Scalar 1000 641 firmware release adds one new enhancement that extend the capabilities of the Scalar 1000 Library. This document describes the new enhancement, as well as corrections made to issues encountered in previous releases of the library. Visit Scalar 1000 641 Firmware and previous releases.
  • Page 2: Compatibility Matrix

    Compatibility Matrix Refer to Table 1 for information on drive and auxiliary firmware compatibility with Scalar 1000 641 firmware. Table 1 Drive and Auxiliary Firmware Compatibility Matrix Component SNCs SNC 3000 SNC 5100 Scalar DLC Drive Types LTO-1 LTO-2 AIT-1...
  • Page 3: Resolved Issues

    Resolved Issues Problems resolved in this release of Scalar 1000 641 Firmware are as follows: Change Request Number 25122 SAC 93 errors sometimes occurred on drives while reinitializing the library. To help eliminate these errors, there is now a 5 second waiting period for IBM LTO drives. If an ACK is not returned for the drive, there are two retries, resulting in a 15-second total time out.
  • Page 4: Known Issues

    Documentation The following documents are currently available for the Scalar 1000: Document Number 6-01150-01 Scalar 1000 Planning Guide...

Table of Contents