22 June 2004
Element
Accept
If Y is selected for the Accept parameter value, the
Response Dialog appears. See Figure 5-90. Otherwise,
the changed actions continue to display but no action is
taken.
Type
: DLT IE
Coord
: I 01 1 A 12
Address : 0027
Index
: 1193
Figure 5-90
Response Dialog
Parameter
Type
Coord
Address
Index
The fifth field indicates the row
of the column.
(01–12 for ½-inch and SDLT/
DLT coordinates)
(01–14 for LTO coordinates)
(01–18 for AIT coordinates)
Displays the element number
that corresponds to the
coordinate parameter.
Y to accept changes
N to reject changes
[more]
Value
Displays the element type
(3480 IE, SDLT/DLT IE,
MIXED IE, AIT IE, LTO IE,
3480 STOR, DLT STOR, AIT
STOR, LTO STOR, 3480
DRIVE, 3590 DRIVE, NCTP
DRIVE, DLT4 DRIVE, SDLT
220, SDLT 320, DRIVE, DLT7
DRIVE,
AIT DRIVE, LTO 1 DRIVE,
LTO 2 DRIVE).
Displays the element
coordinate location.
Displays the current SCSI
element address.
Displays the database element
index.
Database Menu