Declaring A Cleaning Cartridge; Figure 6-10 Media Dialog; Figure 6-11 Selected Cleaning Tape - Quantum Scalar 1000 Operator's Manual

Quantum scalar 1000: user guide
Hide thumbs Also See for Scalar 1000:
Table of Contents

Advertisement

Declaring a Cleaning Cartridge

Note
It is suggested that
cleaning tapes have
white labels and the
first three letters for
the Volser number
are CLN.
22 June 2004
The Expired Tapes method. Refer to Expired Tapes on page
5-55 for more information.
The Coordinate Dialog method. Refer to By Coordinate
Dialog on page 5-57 for more information.
The Volser Dialog method. Refer to By Volser Dialog on
page 5-60 for more information.
If a cleaning cartridge has been introduced into the library by
means other than Insert Cleaning Tape, use this menu to
inform the library that this tape is a Cleaning Tape. For further
information, refer to Media Dialog on page 5-94.
Path:
Setup Menu Cleaning Submenu Media
Dialog
Step 1
Follow the path and the Media Dialog appears.
See Figure 6-10.
Media Type: LTO <
BC : AAAAAA
Continue: N
Figure 6-10
Media Dialog
Step 2
Enter the Media Type (DLT, SDLT, AIT, LTO, 3480/
90E, 3590, NCTP), BC (Barcode of cleaning tape you
want to declare. Use an
See Figure 6-11.
Media Type: LTO <
BC : CLN001
Continue: N
Figure 6-11
Selected Cleaning Tape
*
for ranges of barcodes).