Quantum Scalar 1000 Operator's Manual page 267

Quantum scalar 1000: user guide
Hide thumbs Also See for Scalar 1000:
Table of Contents

Advertisement

Table 7-1
Reported
SAC
78
A Put command is issued but the sensor indicated that the cartridge is not
present in the Gripper Assembly.
Action 1
Check the Gripper Assembly and see if a cartridge is present.
Action 2
Perform a Teach Current operation (Main Menu Service Teach Teach
Current).
Action 3
Do one of the following:
• If a cartridge is found, contact ATAC. For contact information, refer to ADIC
Technical Assistance Center on page 1-5.
• If no cartridge is found in the Gripper Assembly, perform the actions in SAC
02.
79
Failures detected in putting a cartridge into a SDLT/DLT tape drive.
Action 1
Check the SDLT/DLT tape drive to ensure that it is powered on and working
properly. Refer to the SDLT/DLT Maintenance Guide for any SDLT/DLT drive
problem.
Action 2
Perform a Teach Current operation (Main Menu Service Teach Teach
Current).
Action 3
If the problem is not corrected or persists, contact ATAC. For contact
information, refer to ADIC Technical Assistance Center on page 1-5.
7A
Failures detected in the Gripper Assembly Reach/Retract operations.
Action 1
Perform a Teach Current operation (Main Menu Service Teach Teach
Current).
Action 2
If the problem is not corrected or persists, contact ATAC. For contact
information, refer to ADIC Technical Assistance Center on page 1-5.
22 June 2004
SAC Reporting (Continued)
Perform these actions
Service Action Codes
7-15

Advertisement

Table of Contents
loading