Advanced Dialog - Quantum Scalar 1000 Operator's Manual

Quantum scalar 1000: user guide
Hide thumbs Also See for Scalar 1000:
Table of Contents

Advertisement

22 June 2004

Advanced Dialog

Path: Main Menu Setup Menu Advanced Dialog
Use the Advanced Dialog to enable or disable the
automatic configuration, calibration, or cartridge scan when
the library power has been cycled. See Figure 5-119.
If Auto Inventory is disabled, the element status is not
known until the host issues an Initialize Element Status
command or an Inventory is performed via the Operator
Panel.
If Auto Inventory is enabled, an automatic cartridge
inventory is executed on each power cycle.
Any changes in the Operating Mode parameter value should
be made by authorized Service Personnel.
The default is set to 02.
Auto Teach
Auto Inventory:
Operating Mode:
Figure 5-119
Parameter
Auto Teach
Auto Inventory
Operating Mode
:
Y<
Y
02
Accept: N

Advanced Dialog

Value
Y to enable Auto Teach for
automatic configuration and
calibration on each power
cycle
N to disable Auto Teach on
each power cycle
Y to enable Auto Inventory for
automatic cartridge scanning
inventory on each power cycle
N to disable Auto Inventory on
each power cycle
0 to select no library initiated
UNLOAD command before a
move.
1 to select a three second delay
before a Get operation is
performed on a SDLT/DLT
drive after detecting that a tape
Setup Menu
5-89