By Coordinate Dialog

Path: Main Menu Commands Menu Insert/Eject
Eject Clean Tape Submenu By Coordinate
Use the By Coordinate Dialog to remove a cleaning
cartridge without opening the service or access door, or
without host intervention. See Figure 5-80 on page 5-58.
If a Move Media is attempted without an inventory, the
following screen appears. See Figure 5-78.
-=> WARNING <=-
The library may not
be inventoried.
Continue : N
Figure 5-78
Warning Dialog
Parameter
Continue
If Y is selected for the Continue parameter, the Warning
message is removed.
If the Partitioned flag is set, the following screen appears.
See Figure 5-79.
-=> WARNING <=-
Moving tapes may
corrupt partitions.
Continue : N
Figure 5-79
Warning Dialog
Parameter
Continue
Value
Y to continue
N to return to the previous
menu
Value
Y to continue
N to return to the previous
menu
Commands Menu