Table 7-1
Reported
SAC
7E
Failures detected while pushing a cartridge into a tape drive feed slot.
Action 1
Check the cartridge for any physical damage.
Action 2
Perform a Teach Current operation (Main Menu Service Teach Teach
Current).
Action 3
If there is no physical damage to the cartridge, contact ATAC. For contact
information, refer to ADIC Technical Assistance Center on page 1-5.
80
Failures detected in the X-Axis Servo system.
Action 1
Contact ATAC. For contact information, refer to ADIC Technical Assistance
Center on page 1-5.
81
Failures detected in the Y-Axis Servo system.
Action 1
Contact ATAC. For contact information, refer to ADIC Technical Assistance
Center on page 1-5.
82
An unexpected Motors Control condition was received.
Action 1
Contact ATAC. For contact information, refer to ADIC Technical Assistance
Center on page 1-5.
83
The Locate Fiducial Command failed with no target found. This failure
happens most likely during an initial installation of the library.
Action 1
Contact ATAC. For contact information, refer to ADIC Technical Assistance
Center on page 1-5.
84
Y-Axis failed to reach target.
Action 1
Contact ATAC. For contact information, refer to ADIC Technical Assistance
Center on page 1-5.
22 June 2004
SAC Reporting (Continued)