This topic applies to hardware devices in the EX Series product family, which includes switches and the
XRE200 External Routing Engine, that support the LCD panel interface.
The LCD panel on the front panel of EX Series switches displays a variety of information about the
switch in the Status menu and provides the Maintenance menu to enable you to perform basic
operations such as initial setup and reboot. You can disable these menus or individual menu options if
you do not want switch users to use them. You can also set a custom message that will be displayed on
the panel.

Disabling or Enabling Menus and Menu Options on the LCD Panel

By default, the Maintenance menu, the Status menu, and the options in those menus in the LCD panel
are enabled. Users can configure and troubleshoot the switch by using the Maintenance menu and view
certain details about the switch by using the Status menu.
If you do not want users to be able to use those menus or some of the menu options, you can disable
the menus or individual menu options. You can reenable the menus or menu options.
Issue the show chassis lcd menu operational mode command to see the menus or menu options that are
currently enabled.
NOTE: On some platforms, you must specify an FPC slot number in these commands. See the
lcd-menu
statement for details.
To disable a menu:
[edit]
user@switch# set chassis lcd-menu menu-item
To enable a menu:
[edit]
user@switch# delete chassis lcd-menu menu-item
To disable a menu option:
[edit]
user@switch# set chassis lcd-menu menu-item
menu-name disable
menu-name disable
menu-option disable