• For EX4300-48MP and EX4300-48MP-S switches:
• QSFP+ ports
By default, the built-in QSFP+ ports are dedicated VCPs. In 48-port EX4300 switches except
EX4300-48MP and EX4300-48MP-S switches, you can use the QSFP+ ports as network ports or as
VCPs. You can also use the SFP+ uplink module ports to connect members of a Virtual Chassis or a
VCF across multiple wiring closets by configuring these ports as VCPs.
In EX4300-48MP and EX4300-48MP-S switches, you can use only the built-in QSFP+ ports as VCPs
to connect the switch in a Virtual Chassis. You cannot configure the ports on the uplink module in
EX4300-48MP and EX4300-48MP-S switches to Virtual Chassis ports (VCPs). You cannot configure
the built-in QSFP+ ports as network ports.
NOTE: EX4300-48MP switches can be a part of an EX4300 Virtual Chassis with other
EX4300 switches only. If you want to create a Virtual Chassis comprising EX4300-48MP
switch and other EX4300 switches, you must connect it to a 40-Gbps port on the other
EX4300 switches in the Virtual Chassis configuration. In a Virtual Chassis configuration
comprising EX4300-48MP switches, EX4300 switches can be configured only in the line card
role.
For more information about Virtual Chassis, see
information about VCFs, see
Power Supplies
EX4300 switches except EX4300-48MP and EX4300-48MP-S switches support AC or DC power
supplies with different airflow directions. EX4300-48MP and EX4300-48MP-S switches support only
AC power supplies with front-to-back airflow. Power supplies for the EX4300 switch are fully
redundant, load-sharing, and hot-removable and hot-insertable FRUs. All the EX4300 switch models
except EX4300-24T-S, EX4300-24P-S, EX4300-32F-S, EX4300-48T-S, EX4300-48P-S, and
EX4300-48MP-S switches are shipped with one power supply preinstalled in the rear panel of the
switches. EX4300-24T-S, EX4300-24P-S, EX4300-32F-S, EX4300-48T-S, EX4300-48P-S, and
EX4300-48MP-S switches are not shipped with preinstalled power supplies; you must order the power
supplies separately.
Each power supply has a label—AIR IN (AFI) or AIR OUT (AFO)—on the faceplate of the power supply
that indicates the direction of airflow. AIR IN (AFI) labels indicate back-to-front airflow while AIR OUT
(AFO) labels indicate front-to-back airflow.
Table 7 on page 23
lists the AC and DC power supplies used in EX4300 switches and the direction of
airflow in them.