NOTE: Do not overheat the tubing.
Figure 68: How to Install Heat-Shrink Tubing
4.
Ensure that the input circuit breaker is open so that the voltage across the DC power source cable
leads is 0 V and that the cable leads will not become active while you are connecting DC power.
NOTE: The V+ terminals are referred to as +RTN and V– terminals are referred to as –48 V
DC Power Wiring Sequence Warning
in
5.
Ensure that the power supplies are fully inserted in the chassis.
6.
Remove the terminal block cover. The terminal block cover is a piece of clear plastic that snaps into
place over the terminal block.
7.
Remove the screws on the terminals by using the screwdriver. Save the screws.
WARNING: Ensure that the power cables do not block access to switch
components or drape where people can trip on them.
DC Power Electrical Safety Guidelines
and