• If one power supply is installed in the switch:
System power budget = Output wattage of the installed power supply (PSU(W))
• If two power supplies are installed in the switch:
System power budget = (Sum of the output wattage of the two power supplies) – (10% of the output
wattage of the installed power supply)
System power budget = PSU
Table 49 on page 116
lists the
supplies.
NOTE: The DC power supply in the switch does not support Power over Ethernet (PoE); you can
use either an external power injector or an AC power supply to supply power to PoE devices that
you connect to the switch. 32-port EX4300 switches does not support Power over Ethernet
(PoE).
Table 49: N+0 DC Power Calculations for EX4300 Switch Configurations
Switch Configuration
24-port EX4300 switch
32-port EX4300 switch
48-port EX4300 switch
(W) + PSU
(W) – (0.10 x (PSU(W))
0
1
N +0 power calculation for EX4300 switches that use 550 W DC power
Number of
Total Power
Power Supplies
(in watts)
1
550
2
1100
1
550
2
1100
1
550
2
1100
Usable System
Backup Power
Power (in
(in watts)
watts)
550
0
1045
550
550
0
550
550
550
0
1045
550
116
Base Power
(in watts)
150
150
149
160
175
175