Table 11: LCD Panel Menu Options in EX4300 Switches
Menu Label
Description
MAINT
The Maintenance menu has the following options to configure and troubleshoot the
(Maintenance
switch:
Menu)
SYSTEM HALT?—Choose one of the following:
Press Enter to halt the switch. Press Enter again to confirm the halt.
Press Menu to go to the next option in the Maintenance menu.
SYSTEM REBOOT?—Choose one of the following:
Press Enter to reboot the switch. Press Enter again to confirm the reboot.
Press Menu to go to the next option in the Maintenance menu.
LOAD RESCUE?—Choose one of the following:
Press Enter to roll back the switch to the previous valid configuration. Press Enter
again to confirm the rollback.
Press Menu to go to the next option in the Maintenance menu.
REQUEST VC PORT?—Choose one of the following:
Press the Enter button to configure an uplink module port or a built-in QSFP+ port
to be a VCP or to delete a VCP from the switch configuration (when you delete the
VCP, the port is reset to be an uplink module port or a network port).
Press the Menu button to go to the next option in the Maintenance menu.
FACTORY DEFAULT?—Choose one of the following:
Press Enter to restore the switch to the factory default configuration. Press Enter
again to confirm the restoration. The LCD panel flashes a success or failure
message, after which it displays the Idle menu.
Press Menu to go to the next option in the Maintenance menu.
ENTER EZSETUP?—Choose one of the following:
Press Enter to launch EZSetup. Press Enter again to confirm the launch.