Configuring Digitone Receivers - Nortel 1000E Installation And Configuration Manual

Nortel 1000e server: install guide
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

Page 214 of 488
LD 97 – Configuring the MG 1000E ports (Part 2 of 2)
Prompt
Response
ZONE0
0-255
VXTC0
l x
IPR1
xx.xx.xx.xx
ZONE1
0-255
VXCT1
l x

Configuring Digitone Receivers

553-3041-210
Standard 4.00
Configuring the CS 1000E Call Server
Comment
First MG 1000E zone number
First MG 1000E Virtual conference circuit starting loop
number. Two consecutive VXCTs are assigned.
The VXCTs must be previously configured in LD 17.
Where:
l = 0-252
x = 0 means 1 TDS loop only.
x = 1 means 1 TDS loop and 1 conference loop.
x = 2 means 2 TDS loops and 2 conference loops.
x = 3 means 2 TDS loops and 3 conference loops.
x = 4 means 2 TDS loops and 4 conference loops.
Precede with X to remove.
IP address of second MG 1000E cabinet uplink IP address;
<cr> to skip to IPR2 when configuring new superloop.
Second MG 1000E zone number
Second MG 1000E Virtual conference circuit starting loop
number. Two consecutive VXCTs are assigned.
The VXCTs must be previously configured in LD 17.
Where:
l = 0-252
x = 0 means 1 TDS loop only.
x = 1 means 1 TDS loop and 1 conference loop.
x = 2 means 2 TDS loops and 2 conference loops.
x = 3 means 2 TDS loops and 3 conference loops.
x = 4 means 2 TDS loops and 4 conference loops.
Precede with X to remove.
Digitone Receivers must be configured in each MG 1000E if any analog
terminals or trunks are equipped. The loop of the Digitone Receivers is the
September 2007