Checking Mg 1000T Trunking Functionality; Establish Cs 1000E Did Calls From Mg 1000T - Nortel 1000E Installation And Configuration Manual

Nortel 1000e server: install guide
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

Checking MG 1000T trunking functionality

Establish CS 1000E DID calls from MG 1000T

To check trunking on the MG 1000T follow Procedure 73 on
Procedure 73
Checking the status of the MG 1000T trunks
1
Install an i2050 on MG 1000T core. Refer to IP Line: Description,
Installation, and Operation (553-3001-365) for additional information.
2
Establish a call from the i2050 to a telephone on CS 1000E using CDP
number.
3
Establish a call from i2050 to the PSTN.
4
Establish a call from the i2050 to a telephone on the CS 1000E through
the PSTN using <local AC code> <NXX>, for example 9-967-5555.
To check CS 1000E DID calls from MG 1000T follow procedure
To terminate incoming DID calls the number of digits picked up at the
terminating node for call termination, from the Called Number of the message
is based on the length of LDN value. LDN0 is considered for this by default.
Therefore to ensure that all the five digits of the DN are considered for call
termination LDN0 should have a five digit number.
Procedure 74
Check CS 1000E DID calls from MG 1000T
1
Establish a Listed Directory Number in LD 15.
2
Ensure that all the digits of the DN are considered for call termination,
LDN0 should be a number whose length is equal to the maximum length
DN on the Node.
For example, if DNs are five digits, then LDN0 could be configured as
55555.
3
Establish a DID call.
Communication Server 1000E
Verifying the network
End of Procedure
End of Procedure
Installation and Configuration
Page 287 of 488
page
287.